Polyscience
PolyScience is a leading manufacturer of constant temperature control equipment. Since 1963, they have been providing innovative temperature control solutions to global customers. They also supply chilled circulating water baths.
Prolyse BV is the importer of Polyscience products for the Benelux countries.
Best Lab Partner
Available in 40 different models, the latest generation PolyScience cooled circulator water heaters maintain the reputation for innovation, product quality, and heating expertise. The water heaters are extremely easy to operate, easy to install and maintain, and will provide you with years of reliable and accurate heating and cooling.
Characteristics
- quiet
- Easy to maintain
- energy saving
- safe
- Intuitive
- Versatile
- Many controllers available
Solutions
Polyscience offers a wide range of solutions for applications where cooling is required, the so-called cooled circulating water baths. Polyscience water baths are distinguished by their innovative microprocessor-controlled temperature controls. The Polyscience cooled circulating water baths also offer an excellent price-quality ratio. The Polyscience program includes cooling units, (circulating) water baths and temperature controllers for both laboratory and industrial use with excellent specifications.
Versatile range of products for every need
Accurate cooled circulating water baths
Suitable for temperatures down to -40C, Polyscience cooled circulating water baths provide reliable and superior temperature control for a wide range of laboratory cooling applications.
Some characteristics
- Operating temperatures from -40 to 200 °C
- temperature stability of +/- 0.005C
- Capacity from 7 to 45 liters
- six types of controllers with large, intuitive displays and multiple communication options
- Large bath openings and easy-to-clean surfaces
- Rotatable 180 degrees Rotating Controller
- LidDock lid system
- DuraTop Chemically resistant surface
- WhisperCool Environment Control System
- Cool Command Technology
Selecting chilled circulating water baths
Coolers provide heat removal for a wide range of processes and equipment. With the right size and selection of water baths, a cooling circulation water bath increases production speed and accuracy. In addition, it protects valuable process equipment, reduces water consumption and the associated costs. If it is too small, it becomes inefficient due to excessive cooling. For adequate cooling with sufficient capacity, the chiller must supply the cooling fluid at the correct pressure and flow rate. We can help you make the right selection.
The four most important factors that influence the selection of a cooling circulation water bath.
1) Desired coolant temperature
This is the temperature of the coolant in the inlet of your process or equipment. It is important to measure this as the coolant from the cooler flows into the process or instrument. The longer the distance, the higher the potential cooling capacity required. This cooling capacity can be minimized by installing insulating cladding on the pipes and placing the water bath as close as possible to the process or instrument.
2) Heat load
This is the amount of heat that needs to be removed. This is usually expressed in BTU/hour or watts. The heat load value is often determined by the manufacturer of the equipment. If not, it can be calculated using the following formula:
Heat load = flow rate x liquid density x liquid specific heat x constant x d°C
d°C = the difference between the inlet and outlet temperatures of the equipment that is being cooled.
3) Cooling fluid flow and pressure
These parameters are usually supplied by the manufacturer of the equipment and are a function of the surface area and heat transfer characteristics of the process/material being cooled. It is crucial that your cooled circulating water baths use the correct flow rate and pressure of coolant. If the flow rate or pressure is too high, the equipment being cooled may be damaged. If it is too low, the heat removal may be insufficient, with all the consequences that follow. Prolyse BV can help you determine the type and size of the coolant pump that is most suitable for your needs.
4) Condenser heat output
Another factor is the selection of the cooler/heat exchanger and how the heat will be removed. The coolers of the air-cooled condensers give off heat to the outside air and require some power and ventilation for operation. Coolers of water-cooled condensers dissipate heat onto the cooling water that flows through them.
5) Recommended coolant
The most common and acceptable coolant is a mixture of 50% water and 50% ethylene glycol ethylen (polycool, e.g. EG-25). This combination provides the best results for the setpoint temperature between -25 °C and 80 °C. Although ethylene glycol is not required for temperatures above the freezing point (0 °C), it is highly recommended. Glycol helps lubricate the seals and the liquid temperature inside the cooler can easily be around or below the freezing point without problems.
6 types of controllers are available
- Programmable controller with high performance
- Advanced programmable controller
- Digital controller
- Advanced digital controller
- Standard digital controller
- MX Controller

